Medtronic's Evolut PRO Now Available in Europe
Next Generation of CoreValve Gains CE Mark
Indicated for Symptomatic Patients at Intermediate, High or Extreme Risk for Surgery
Share This Story:
Email
Bookmark and Share


external sites:
Medtronic plc.

Medtronic CoreValve
Evolut PRO
Medtronic CoreValve
Evolut PRO
July 31, 2017 -- This morning Medtronic announced that its latest transcatheter aortic valve, the CoreValve Evolut PRO, has received the CE mark and is now available for use in Europe. In a reversal of the usual order of device approvals, FDA approval pre-dated the CE Mark - the Evolut PRO was first given an FDA okay back in March.

This new generation valve utilizes a biocompatible porcine outer wrap that increases surface contact and sealing to reduce paravavular leaks (PVL). In the clinical study of 60 patients presented at this year's American College of Cardiology meeting, almost three-quarters of the patients had no or only trace PVL, and at 30 days none had experienced moderate or severe PVL.

Another major improvement over earlier iterations was the reduced necessity for permanent pacemaker implantation: only 10% in this cohort.

The 30-day outcome data showed a low 1.7% rate of disabling stroke and high hemodynamic performance with aortic valve areas of 2.0 ± 0.5cm2, and mean gradients of 6.4 ± 2.1mm Hg.

This morning's press release from Medtronic follows:

Medtronic Announces CE Mark and European Launch of CoreValve™ Evolut™ PRO Transcatheter Valve with Advanced Sealing

July 31, 2017 -- Dublin -- Medtronic plc (NYSE:MDT) today announced CE (Conformité Européenne) mark and European launch of the CoreValve™ Evolut™ PRO valve for the treatment of severe aortic stenosis for symptomatic patients who are at intermediate, high or extreme risk for open heart surgery. Clinical data for the Evolut PRO valve was recently unveiled at the American College of Cardiology (ACC) 66th Annual Scientific Session, and showed high survival, low rates of stroke, minimal paravalvular leak (PVL) and excellent hemodynamics.

The Evolut PRO device features a unique valve design with an outer wrap that adds surface area contact between the valve and the native aortic annulus to further advance valve sealing performance. The biocompatible porcine pericardial tissue wrap, in addition to other design elements, is incorporated to address the occurrence of blood leaking through the sides of the valve.

Dr. Nicolas M. Van Mieghem
Dr. Nicolas M. Van Mieghem

"The Evolut PRO valve has shown impressive clinical outcomes, with low paravalvular leak and pacemaker rates," said Nicolas M. Van Mieghem, MD, director of interventional cardiology at Erasmus Medical Center in Rotterdam, The Netherlands. "With its ease-of-use and deliverability, the Evolut PRO valve will bring TAVI practice to a higher level, and I look forward to seeing it utilized in patients across Europe."

The Evolut PRO Clinical Study (N=60) met its primary endpoint at 30 days with high rates of survival (98.3 percent) and low rates of disabling stroke (1.7 percent). The Evolut PRO valve also showed strong hemodynamic performance with large aortic valve areas (2.0 ± 0.5cm2) and mean gradients in the single digits (6.4 ± 2.1mm Hg) at 30 days. The majority of study subjects (72.4 percent) experienced no/trace PVL and no incidents of moderate or severe PVL were observed at 30 days. Additionally, improving on the already low rates seen in Evolut R clinical studies and real-world TVT and FORWARD registries, the rate of new pacemaker implantation was 10 percent.

Built on the proven platform of the recapturable CoreValve Evolut R System, the Evolut PRO valve includes a self-expanding nitinol frame with its supra-annular valve position that helps achieve excellent hemodynamic performance.

"We are excited to introduce the next evolution of our Evolut TAVI platform to provide physicians in Europe with a comprehensive portfolio to address their patients' needs," said Rhonda Robb, vice president and general manager of the Heart Valve Therapies business, a part of Medtronic's Cardiac and Vascular Group.

The Evolut PRO System is delivered through the EnVeo™ R Delivery Catheter System and is indicated for vessels down to 5.5mm. The EnVeo R system features an InLine Sheath that makes it the lowest delivery platform currently on the market. It also provides a greater opportunity to treat patients with smaller vessels through the preferred transfemoral access route.

The 23mm, 26mm and 29mm sizes of the Evolut PRO System received FDA approval in March 2017 and are available for use in the United States.

In collaboration with leading clinicians, researchers and scientists worldwide, Medtronic offers the broadest range of innovative medical technology for the interventional and surgical treatment of cardiovascular disease and cardiac arrhythmias. The company strives to offer products and services that deliver clinical and economic value to healthcare consumers and providers around the world.

About Medtronic
Medtronic plc (www.medtronic.com), headquartered in Dublin, Ireland, is among the world's largest medical technology, services and solutions companies - alleviating pain, restoring health and extending life for millions of people around the world. Medtronic employs more than 91,000 people worldwide, serving physicians, hospitals and patients in approximately 160 countries. The company is focused on collaborating with stakeholders around the world to take healthcare Further, Together.