Category Archives: Cardiac CT

AimRADIAL Masterclass V + FFR Workshop in Budapest

budapest_palaceOn September 22-23, 2016, the 5th Advanced International Masterclass on the Transradial Approach will be held in Budapest, Hungary. And this year, AimRADIAL will be preceded on September 21 by a one-day comprehensive workshop covering all aspects of Fractional Flow Reserve (FFR) from the basic principles and set-up in the cath lab, to the differences between FFR, iFR, and CFR, a comprehensive review of the clinical study data so far, and finally a look at future modalities, like FFR-CT (although the title of that talk by Dr. Nick Curzen is “FFR-CT: the future is now“). Continue reading

Leave a Comment

Filed under Angiograms, Cardiac CT, FAME I / FAME II, FFR, Global Trends, iFR, Medical Education, Meetings & Conferences, Patient Experience, Transradial Approach

Consumer Reports Overstates Cardiac CT Radiation Dose

  Consumer Reports regularly publishes health information to aid the consumer/patient in making decisions. And that’s a good thing. But also important is having the most current information, which their January 27, 2015 article, titled “The surprising dangers of CT scans and X-rays,” does not.

All of the cautions about imaging tests that are listed in the Consumer Reports article are valid: ask why the test is necessary; check the credentials of the imaging specialist; ask for the lowest effective dose; avoid unnecessary repeat scans.

But one important piece of data is almost a decade old and, as a result, is potentially misleading. I’m talking about the radiation dose from a Cardiac CT scan. The article states that a Cardiac CT Angiogram (CTA) exposes the patient to 12 mSv of ionizing radiation, or 120 times that of a chest X-ray. This was true years ago, when CTA was first being used to diagnose coronary artery disease. But it is not true today. Continue reading

7 Comments

Filed under Cardiac CT, Imaging, Media Coverage, Non-Invasive Testing

Philips Buys Volcano: It’s About Money, Technology, and History

  Rumors and theories about an acquisition of Volcano Corporation (NASDAQ: VOLC) had been circulating for quite some time: months, years even. The company seemed an obvious choice: it has an advanced intravascular ultrasound (IVUS) technology that leads the market, with Boston Scientific coming in second; it has a fractional flow reserve (FFR) wire that splits the market with St. Jude Medical; and recently Volcano gained FDA approval for its Instant Wave-Free Ratio (iFR) physiologic measurement product, a faster, cheaper potential alternative to FFR. Continue reading

Leave a Comment

Filed under ACC, Angiograms, Back to the Future, Business & Industry, Cardiac CT, Cost Effectiveness, FFR, Global Trends, History, Imaging, Intravascular Guidance, IVUS, OCT, Video

George W. Bush Gets Angioplasty and Stent – Was It Necessary?

George W BushFormer President George W. Bush received an angioplasty and stent this morning at Texas Health Presbyterian Hospital Dallas. The stent was recommended by Bush’s doctors to open a blockage in one of his coronary arteries, found yesterday during what was described by Bush spokesman Freddy Ford as his annual physical exam at the Cooper Clinic in Dallas. Continue reading

9 Comments

Filed under Angiograms, Appropriate Use Criteria (AUC), Cardiac CT, Celebrity Patients, COURAGE, Drug-Eluting Stents, FFR, Imaging, Media Coverage, Non-Invasive Testing, Optimal Medical Therapy, Stent